Facilities
We have a wide range of highly specified facilities and equipment available for use. These include:
- Laboratories and Test Equipment (including flexure rigs)
- 13 lab areas (maximum lab height is 6.5 m) including large lab with overhead crane
- Can handle equipment up to mass of 10 tonnes
- Lab facilities (compressed air, water cooling, chilled water etc.)
- US power supply (110 V 60 Hz)
- 3 flexure rigs; maximum test capacity is 10 tonnes and 3 cubic metres.
- Test Cryostats
- Test cryostats (various sizes; temperatures down to 4 K)
- Includes a large (1 m diameter) cryostat operating to 20 K.
- Cryogenic support equipment (liquid nitrogen and helium, leak detectors etc.)
- Clean Rooms
- 4 m x 2 m class 1000 clean room with class 100 laminar flow cabinet, used for electronic
- Device assembly.
- 6 m x 4 m class 1000 clean room (currently dedicated to one project)
- 4 m x 4 m tented class 10 000 clean room
- Mechanical Workshop
- CNC and manual mills and lathes
- CMM in semi-clean area (used to check part dimensions after manufacture, and also for system alignment). Covers area of 700
- mm x 700 mm x 500 mm; resolution approximately 1.5 μm
- Electronics
- Lexica microscope with TV camera and frame grabber, located in class 1000 clean room
- Two complete data acquisition systems for CCD/Infra-red array measurements (32 channels, 1 MHz sampling per channel
- SDSU III/ARC controllers)
- Full scanning monochromater (used for absolute quantum efficiency measurements at optical/IR wavelengths (0.04 to 1.5 μm)
- NPL calibrated diodes for calibrating optical CCD detectors
- Test cryostats for IR detector characterization (cool to 45 K using closed cycle coolers)
- JHK band filters (1 to 2.5 μm)
- Fe55 X-ray source (used to measure charge transfer efficiency of CCDs)
- Calibrated 4 inch square black body source
- Full FPGA design environment (Altera devices)
- Software: Protel for schematic capture, PSPICE
- Optics
- 6 large optical benches
- Three portable fully phase shifting optical interferometers (used to measure flatness etc.) - up to 100 mm beam diameter
- Perkin Elmer spectrophotometer (0.4 - 3 μm) (used for measuring filter transmission etc.)
- 2 alignment telescopes
- TM5100A theodolite
- Cooled CCD camera